G8MNY  > TECH     25.04.24 03:02z 45 Lines 1415 Bytes #30 (0) @ WW
BID : 5565_GB7CIP
Subj: TNC-PC Clock Basic program
Path: SR8BBS<SR4BBX<DB0RES<DB0ERF<IZ3LSV<I0OJJ<GB7CIP
Sent: 240416/0640Z @:GB7CIP.#32.GBR.EURO #:5565 [Caterham Surrey GBR] $:5565_GB
From: G8MNY@GB7CIP.#32.GBR.EURO
To  : TECH@WW

By G8MNY                                (New Jul 11)

Here is an old Basic program by G4WGZ to get the time & date from your 24/7
powered TNC & use it at boot time in the PC is the PC's battery clock is duff.

It was for a DOS computer, but compiled or using a batch file it should be
usable on a modern PC with this clock fault.

Save the next bit as TNCLOCK.BAS
---------------------------------------------------------------   
1 'Prog to get TNC time & put it in the PC. by G4WGZ
5 TRY=1
10 OPEN"COM1:9600,N,8" AS #1
20 IF TRY>5 THEN PRINT"CLOCK NOT SET":SYSTEM
25 IF EOF(1) THEN PRINT#1,"DA"
30 INPUT#1,DA$:PRINT DA$
32 IF INSTR("?clock",DA$)>0 THEN TRY=6:GOTO 20
35 IF LEN(DA$)>18 THEN DA$=RIGHT$(DA$,18)
40 IF LEN(DA$)<18 OR MID$(DA$,3,1)<>"/" THEN TRY=TRY+1:GOTO 20
50 DATE$=MID$(DA$,4,2)+"-"+LEFT$(DA$,2)+"-"+MID$(DA$,7,2)
60 TIME$=RIGHT$(DA$,8)
70 PRINT"CLOCK SET OK"
80 SYSTEM
---------------------------------------------------------------
Line 10 assumes your TNC's COM port is port 1 & usees 9k6, 8 bit etc.


Put this next command line in AUOEXEC.BAT or in a start up program list.
------------------------------------------
BASIC TNCLOCK
------------------------------------------
(or whatever Basic U have)



That is it, if the TNC clock is OK the PC clock will be updated on boot.


Why don't U send an interesting bul?

73 De John, G8MNY @ GB7CIP