G8MNY  > TECHNI   02.09.25 23:04z 73 Lines 3219 Bytes #24 (0) @ WW
BID : 40037_GB7CIP
Read: GUEST
Subj: Drake WH7 QRO HF SWR Bridge
Path: SR8BBS<OK0NBR<IW0QNL<HB9ON<DK0WUE<PD0LPM<VE3CGR<OK2PEN<GB7CIP
Sent: 250902/0637Z @:GB7CIP.#32.GBR.EURO #:40037 [Caterham Surrey GBR]
From: G8MNY@GB7CIP.#32.GBR.EURO
To  : TECH@WW

By G8MNY                                        (New Nov 06)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)

I have reverse engineered this QRO Bridge. It was quite straight forward.

SPECIFICATION                                       Ú==================¿
Frequency range  1.8-54MHz                          ³ ÚÄÄÄÄÄÄÄÄ¿       ³
Impedance        50R                                ³ ³ \      ³   o   ³
Peak Power       2kW                                ³ ÃÄÄÄÄÄÄÄÄ´   _   ³
Connection      SO239                               ³  ~~~~~~~~   <_>  ³
Accuracy        ñ(5% of reading +1% of full scale)  ³__________________³
VSWR Insertion  1.05:1                                 ß             ß

THE CIRCUIT
    --------- HEAD UNIT -------
XMTR o)ÄÄÄÄÄÄÄuÄÄÄÄÄÄÄÂÄÄÄÄ(o LOAD
      ÃÄÄÄÄ=======  C1³/\  ³
      ³ T1 ())))))   ===   ³
      ³    ³  ³  ³  /'³    ³
      ÃÄ´ÃÄ)ÄÄÁÄÄ)ÄÄÂÄÁÄ´ÃÄ´
      ³n15 ÃÄ68RÄ´  ³  n15 ³
      ³   _³_   _³_ ÀÄ2K2ÄÄ´      ----------- METER BOX -------
      ³ D1\_/   \_/D2      ³   wh  R \~ ~ ~ ~ ~ ~ \      ___ 200uA
      ³    ³     ÃÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÄo \   VAR  Úo  \   +/SWR\640R
      ³    ³     ³         ³   bn    <ÄÄoÄ68KÄÄ´ <ÄÄoÂÄ<Meter>¿
      ³    ÃÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÄo       SWRÀo    ³  \___/ ³
       ³     ³         ³   gn  F                 À´ÃÄÄÄÄÄÄ´
      ³    ÃÄ68KÄ)Ä20KPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo      10n    ³
      ³    ³     ³         ³   bl         2000W               ³
      ³    ÃÄ10KÄ)Ä20KPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo             ³
      ³    ³     ³         ³   rd          200W               ³
      ³    ÃÄÄÄÄÄ)Ä10KPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo             ³
      ³ 1n===   ===1n      ³   bk           20W               ³
      ÀÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

HOW IT WORKS
A short length of thick wire goes through the screened ferrite transformer T1
making a 1 turn primary, and the lead joins the XTMR & LOAD sockets together. A
pickoff voltage attenuator is formed with trimmer C1 and the 2 150pF caps. This
RF voltage is fed to T1 secondary centre tap. Load current is transformed by T1
into a voltage across the 5W non inductive 68R.

When the load is exactly 50R, diode D2 sees no RF, as the voltage sample and
the current sample are in opposition & cancel dependent on the calibration of
the trimmer C1.

The 2K2 is needed to complete the DC meter circuit and will affect the
calibration of the lowest frequency, as will the L value of T1.

Diode D1 however sees the voltage tap and the current sample added together and
produces DC across the 1nF, and feeds this to the meter box on the brown wire
for SWR full scale, and via the calibration power presets on green, blue & red
wires.

SWR voltage readings will be present on D2 when the load is not exactly 50R are
fed out on the white wire.

The meter box has a 1 wafer switch that forms a 2 switch bank connected as
show, to give all the functions.


See also my Tech buls on "A Homebrew HF SWR Bridge", "PEP Meter modification",
"QRP SWR Bridge", "Meter Damping & Speed Up" & "Palstar AT1500CV ATU", "HF ATU